Enter the IP address of ANC-100e in the Server’s IP Address or hostname: field (Default is 192.168.137.2) 9.
![adding a device to rslinx classic adding a device to rslinx classic](https://i.ytimg.com/vi/xagt1j8VTgs/maxresdefault.jpg)
![adding a device to rslinx classic adding a device to rslinx classic](https://i.pinimg.com/736x/2d/69/c5/2d69c54d3e0aa9246170f2e0a8f89db4.jpg)
#ADDING A DEVICE TO RSLINX CLASSIC DRIVER#
Enter the name for the driver or use the default name 7. If you can ping the device, but RSLinx does not recognize the device, chances are that RSLinx is not configured properly. Select Remote Devices via Linx Gateway from the Drop down list 5. Use the PING command at your command prompt to verify physical connectivity. If your devices are not communicating, verify the cables are hooked up properly, and that you typed in the IP address correctly. In my case, the other two processors are powered down. Here is an example of where one device is communicating, and the others are not. You will see an icon of the device if it is communicating properly, and the EDS File (Electronic Data Sheet) for the device is registered. It’s very easy to mis-type an IP address or hostname.įinally, verify that you are seeing your Ethernet device.
#ADDING A DEVICE TO RSLINX CLASSIC DRIVERS#
Please be sure your drivers are working properly by using the RSWho screen. RSWho will verify communication to your processor. Press OK, and then close the “Configure Drivers” Screen If you are using a host file (or DNS server), you can enter the host names instead of the IP addresses. Usually, we pass this part by typing the name of the device you will connect. If you give a meaningful name here, you can easily find this link on Rslinx while connecting to this device later. Next, verify the name of the driver, then press OK.įinally, enter the IP addresses that you wish to communicate with. Select Ethernet Devices from the list of drivers and click Add button, a window will open where you will select the name you will give to the driver. Here, though, we will be selecting the “Ethernet Devices” Driver. If you choose to use the Ethernet/IP driver, just verify the adapter it is using, and choose to browse the whole subnet. Then, select “Ethernet Devices”, then click “Add New”. It will not “Reverse Resolve” an IP address to a host name if you are using a host file on your computer.Ĭlick Communications | Configure Drivers. The other issue with Ethernet/IP is that it finds only the IP address. The problem with this is that we loose the ability to organize our drivers effectively for different locations. The Ethernet/IP driver will browse the entire subnet to look for devices. Use the “Ethernet Devices” Driver, or the Ethernet/IP driver. There are actually two options for the driver. If you have a shortcut on your desktop, use that to open RSLinx.Ģ) Next, select the “Ethernet Devices” Driver Also I noticed in RSLinx 2.54 that when I have more than one active IP network adapter, a window pops up to let me select which adapter I want to have RSLinx use.
#ADDING A DEVICE TO RSLINX CLASSIC SOFTWARE#
Access RSLinx by clicking Start | All Programs | Rockwell Software | RSLinx | RSLinx classic. In recent versions of RSLinx Classic, you can add ':EIP' to the end of the IP addresses you list in the Ethernet Devices driver configuration to skip the Port 2222 attempts. The purpose of RSLinx is to interface your laptop with your processor. FactoryTalk View SE Trends and Data Logīefore we start, be sure to write down the IP address of your 1756-ENBT or 1756-EN2T (or other ethernet module) You will need that to configure the Ethernet Devices drive.Beginning a FactoryTalk View SE Project.Derivative Settings for ControlLogix PID Enhanced.Integral Settings for ControlLogix PID Enhanced.Proportional Settings for ControlLogix PID Enhanced (PIDE).Proportional, Integral, Derivative (PID).Our local IO network is using EN2TRs (v11.001). I’m using version 4.0 or 4.1 of RSLinx Classic lite (all I can remember is that it starts with a 4). From the local IO network adapter I can add the VFDs using the steps I explained above and then configure it remotely without hauling my ass all the way over to the controller. If I locate my PLC in RSLinx using the 10.x.x.x address, I can drill down and find its local IO network adapter. In my plant, our controllers have an adapter for the plant network(10.x.x.x) and the local IO network(192.168.1.x). This should at least get the device to pop-up as a question mark. Select the unknown device, should be showing as a question mark. If you do not see your device Right-Click on Ethernet, select properties, and you should be able to type in an address inside the subnet and then press the Add button to add it to the expected address list. If RSLinx can see the PLC, however is showing it as an unknown device, this can be solved by the following: Open up RSLinx Classic (in case you where doing Who Online in RSLogix 5000) Select Who Online Line. Expand the “Ethernet” tree under that network card.
![adding a device to rslinx classic adding a device to rslinx classic](https://uploads-ssl.webflow.com/5f7b0ab7d260466bdef601fa/611483b4bffed58593e8b583_1*pfePqhrwydIGVuCs2BHyuA.png)
In that case, one thing you can do is drill down to the devices under your PLCs network card. Did you ever resolve this? I’m going to assume that this device is on the same subnet as your PLC.